Joint Replacement Application Example
Results of prior hematogenous bacterial coxarthritis (Staph. aureus) in a 62-year-old woman.
Pre-operative X rays.
Anteroposterior and lateral views
Cementless prosthetic components coated with DAC® hydrogel combined with 5% Vancomycin.
The DAC® coating is designed to resist during the introduction of a “press-fit” implant.
Insertion of the prosthetic components.